Dionex™ ICS-6000 ED Electrochemical Detector
Dionex™ ICS-6000 ED Electrochemical Detector
Thermo Scientific™

Dionex™ ICS-6000 ED Electrochemical Detector

Get lower backgrounds than ever before with the Thermo Scientific™ Dionex™ ICS-6000 ED Electrochemical Detector.

Have Questions?
Catalog number 072042
Price (CNY)/ Each
-
Description:
Electrochemical Detector (without cell)

Get lower backgrounds than ever before with the Thermo Scientific™ Dionex™ ICS-6000 ED Electrochemical Detector, which is flow- and volume-optimized for high-performance amperometric detection in both capillary and analytical ion chromatography. The detector is now even easier to use with an optional, calibration-free palladium hydrogen reference electrode.

Robust Amperometric Detection
  • Improved performance, reduced band broadening and lower backgrounds with volume- and flow-optimized detector cell, improved reference electrode and minimized dead volume
  • Excellent detection from high to low concentrations with microprocessor-controlled digital signal processing
  • Improved stability and lower noise from the integrated electronics between the cell and detector
  • Easy calibrations and diagnostics from innovative, built-in electronics
  • Simple, snap-in installation automatically recognized by Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System (CDS) software—no cables or tools required
  • Compact installation with minimal tubing lengths for up to two detector modules in the same Dionex ICS-5000+/ICS-6000 DC Detector/Chromatography Compartment
  • Easily reproducible electrode and cell gasket installation thanks to Yoke-Knob design

Flexible Applications
  • Choice of DC amperometry, cyclic voltammetry and integrated amperometry, including three-dimensional—current, voltage, retention
  • Ready to optimize for individual analytes with choice of multiple waveforms and integration times
  • Flexible configuration for use in series with another detector or parallel for dual detection
  • Complete freedom to change waveform profile segments using integrated amperometry mode
  • Choice of control through Chromeleon CDS software or locally through TTL inputs
  • 3-D display of raw integrated amperometry data similar to PDA data display using Chromeleon CDS software 6.8 or later
  • Choice of pH/Ag/AgCl electrode or optional extended-lifetime, reduced-calibration palladium hydrogen reference electrode
Specifications
Analog Outputs10 mV
Automated Start-Up FunctionsYes
AutorangingYes
Cell BodyTitanium
Cell ElectrodesConventional: gold, glassy carbon, platinum, and silver Disposable: gold, platinum, carbon and silver
Cell Volume<0.2 μL
Control ModeLocal or remote control
DescriptionElectrochemical Detector (without cell)
Detection ModeDC/Pulsed/Integrated Amperometry and Cyclic Voltammetry
Detector TypeElectrochemical (ECD)
TypeElectrochemical Detector
Electronic Noise<50 Pc.
Electronics TypeMicroprocessor controlled digital signal processing autoranging
Filter0 to 10s
GLP FeaturesYes
Max. Cell Operating Pressure100 psi
Reference ElectrodepH-Ag/AgCl combination
Working ElectrodesConventional: gold, glassy carbon, platinum, and silver Disposable: gold, platinum, carbon and silver
Weight (Metric)24.5 kg
Unit SizeEach