Thermo Scientific™

Orion™ 2100 Series pH ORP and Conductivity Analyzer

Catalog number: 2100SMK
Thermo Scientific™

Orion™ 2100 Series pH ORP and Conductivity Analyzer

Catalog number: 2100SMK
Measure pH/ORP and conductivity accurately and reliably in the harshest environments with the Thermo Scientific™ Orion™ 2100 Series pH ORP and Conductivity Analyzer. Designed for the highest accuracy and performance, this analyzer has flexible measurement parameters for single, dual or combined pH ORP. Conductivity inputs are offered with optional digital communications.
 
Catalog Number
2100SMK
Unit Size
Each
Description
Sample Panel Mounting Kit
Price (CNY)
Full specifications
DescriptionSample Panel Mounting Kit
TypepH ORP and Conductivity Analyzer
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Second Channel Module for Conductivity
Price (CNY)
Full specifications
DescriptionSecond Channel Module for Conductivity
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Digital Communication Module Modbus RTU Protocol
Price (CNY)
Full specifications
DescriptionDigital Communication Module Modbus RTU Protocol
TypepH ORP and Conductivity Analyzer
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Second Channel Module for pH/ORP
Price (CNY)
Full specifications
DescriptionSecond Channel Module for pH/ORP
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Unit SizeEach
Catalog Number
Unit Size
Each
Description
2102PH Single Channel pH/ORP Analyzer
Price (CNY)
Full specifications
Accuracy±0.01
Accuracy (mV)±0.01
Accuracy (Resistivity)0.5 ±1 digit %
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels1
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2102PH Single Channel pH/ORP Analyzer
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1pH/ORP
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Description
2102 Meter with Dual Channel pH/ORP
Price (CNY)
Full specifications
Accuracy±0.01
Accuracy (mV)±0.01
Accuracy (Resistivity)0.5 ±1 digit %
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels2
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2102 Meter with Dual Channel pH/ORP
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1pH/ORP
Options for Channel 2pH/ORP
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Description
2102PH Dual Channel Analyzer and Ultra Pure Water (UPW) pH Kit
Price (CNY)
Full specifications
Accuracy±0.01
Accuracy (mV)±0.01
Accuracy (Resistivity)0.5 ±1 digit %
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels2
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2102PH Dual Channel Analyzer and Ultra Pure Water (UPW) pH Kit
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Includes2 x 2001SC ROSS pH electrodes, 2 flow cells, 2 x 5 meter electrode cables (2001SM), 2 x PT1000 ATC probes (2001TM) and pH buffers (4, 7 and 10)
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1pH/ORP
Options for Channel 2pH/ORP
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Description
2104 Meter with Dual Channel Conductivity
Price (CNY)
Full specifications
Accuracy±0.01
Accuracy (Resistivity)0.5% ± 1 digit
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels2
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2104 Meter with Dual Channel Conductivity
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1Conductivity
Options for Channel 2Conductivity
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Description
2104CD Single Channel Analyzer and Ultra Pure Water (UPW) Conductivity Kit
Price (CNY)
Full specifications
Accuracy±0.01
Accuracy (Resistivity)0.5% ± 1 digit
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels2
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2104CD Single Channel Analyzer and Ultra Pure Water (UPW) Conductivity Kit
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Includes2002SS conductivity cell, flow cell (2002FC) and 100 uS/cm conductivity standard (011008)
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1Conductivity
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Description
2104CD Dual Channel Analyzer and Ultra Pure Water (UPW) Conductivity Kit
Price (CNY)
Full specifications
Accuracy±0.01
Accuracy (Resistivity)0.5% ± 1 digit
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels2
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2104CD Dual Channel Analyzer and Ultra Pure Water (UPW) Conductivity Kit
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Includes2 x 2002SS conductivity cells, 2 flow cells (2002FC) and 100 uS/cm conductivity standard (011008)
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1Conductivity
Options for Channel 2Conductivity
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
Showing 10 of 11Show more
Catalog NumberSpecificationsUnit SizeDescriptionPrice (CNY)
2100SMKFull specifications
EachSample Panel Mounting KitRequest A Quote
DescriptionSample Panel Mounting Kit
TypepH ORP and Conductivity Analyzer
Unit SizeEach
2100CD2Full specifications
EachSecond Channel Module for ConductivityRequest A Quote
DescriptionSecond Channel Module for Conductivity
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Unit SizeEach
2100DCFull specifications
EachDigital Communication Module Modbus RTU ProtocolRequest A Quote
DescriptionDigital Communication Module Modbus RTU Protocol
TypepH ORP and Conductivity Analyzer
Unit SizeEach
2100PH2Full specifications
EachSecond Channel Module for pH/ORPRequest A Quote
DescriptionSecond Channel Module for pH/ORP
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Unit SizeEach
2102PHFull specifications
Each2102PH Single Channel pH/ORP AnalyzerRequest A Quote
Accuracy±0.01
Accuracy (mV)±0.01
Accuracy (Resistivity)0.5 ±1 digit %
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels1
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2102PH Single Channel pH/ORP Analyzer
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1pH/ORP
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
2102PH2Full specifications
Each2102 Meter with Dual Channel pH/ORPRequest A Quote
Accuracy±0.01
Accuracy (mV)±0.01
Accuracy (Resistivity)0.5 ±1 digit %
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels2
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2102 Meter with Dual Channel pH/ORP
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1pH/ORP
Options for Channel 2pH/ORP
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
2102PH2SCFull specifications
Each2102PH Dual Channel Analyzer and Ultra Pure Water (UPW) pH KitRequest A Quote
Accuracy±0.01
Accuracy (mV)±0.01
Accuracy (Resistivity)0.5 ±1 digit %
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels2
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2102PH Dual Channel Analyzer and Ultra Pure Water (UPW) pH Kit
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Includes2 x 2001SC ROSS pH electrodes, 2 flow cells, 2 x 5 meter electrode cables (2001SM), 2 x PT1000 ATC probes (2001TM) and pH buffers (4, 7 and 10)
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1pH/ORP
Options for Channel 2pH/ORP
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
2104CDFull specifications
Each2104 Meter with Dual Channel ConductivityRequest A Quote
Accuracy±0.01
Accuracy (Resistivity)0.5% ± 1 digit
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels2
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2104 Meter with Dual Channel Conductivity
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1Conductivity
Options for Channel 2Conductivity
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
2104CD1SSFull specifications
Each2104CD Single Channel Analyzer and Ultra Pure Water (UPW) Conductivity KitRequest A Quote
Accuracy±0.01
Accuracy (Resistivity)0.5% ± 1 digit
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels2
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2104CD Single Channel Analyzer and Ultra Pure Water (UPW) Conductivity Kit
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Includes2002SS conductivity cell, flow cell (2002FC) and 100 uS/cm conductivity standard (011008)
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1Conductivity
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
2104CD2SSFull specifications
Each2104CD Dual Channel Analyzer and Ultra Pure Water (UPW) Conductivity KitRequest A Quote
Accuracy±0.01
Accuracy (Resistivity)0.5% ± 1 digit
Accuracy (Temperature)±0.5°C
Alarm Output3 ea.
Analog Outputs2 ea.
Case MaterialValox 364
Certifications/ComplianceCE,CSA, FCC Class A limits
Channels2
Communication DetailsModBus with additional Module
Current Loops4(0) to 20 mA
Description2104CD Dual Channel Analyzer and Ultra Pure Water (UPW) Conductivity Kit
Temperature (Metric) Operating5°C to 45°C
TypepH ORP and Conductivity Analyzer
Display TypeCustom LCD, backlit with scrolling text
Enclosure RatingNEMA 4X IP 65
Includes2 x 2002SS conductivity cells, 2 flow cells (2002FC) and 100 uS/cm conductivity standard (011008)
Keypad TypeMembrane
Max. Relative Humidity5 to 95%, non-condensing
Mounting OptionsPipe, Panel or Wall Mount
Options for Channel 1Conductivity
Options for Channel 2Conductivity
Range (mV)±1999mV
Range (Resistivity)2ohm to 100Mohm
Resolution0.1; 0.01
Resolution (mV)1mV
Resolution (Resistivity)2ohms/cm
Resolution (Temperature)0.1°C
Temperature (English) Operating41°F to 113°F
USB InterfaceNo
Length (Metric)186 mm
Width (Metric)144 mm
Height (Metric)144 mm
Voltage85 to 132 VAC; 170 to 264 VAC
Amperage5A
Frequency0 to 60 Hz
Unit SizeEach
Showing 10 of 11Show more

Features:

  • Single channel or dual channel configurations
  • Optional digital communication boards
  • Provides cation and ammonia/ETA compensation for customizing to your plant's requirement

2100 Series pH Analyzer Consumables Ordering Information:

  • pH Consumables Kit — pH 4.01, 7.00 and 10.01 Buffers and Process Thermo Scientific™ Ross™ Electrode Filling Solution, Cat. No. 2001CP
  • pH 4.01 Buffer, 475mL, Cat. No. 910104
  • pH 7.00 Buffer, 475mL, Cat. No. 910107
  • pH 10.01 Buffer, 475mL, Cat. No. 910110
  • Process Ross Electrode Filling Solution, 5 x 60mL, Cat. No. 2001FS
  • Process Ross Electrode Filling Solution, 4 x 120mL, Cat. No. 2001F4
  • pH Electrode Cleaning Solution A for Protein Removal, 4 x 30mL, Cat. No. 900021
  • pH Electrode Cleaning Solution B for Bacteria Removal, 4 x 60mL, Cat. No. 900022
  • pH Electrode Cleaning Solution C for General Cleaning, 4 x 30mL, Cat. No. 900023
  • pH Electrode Cleaning Solution D for Oil and Grease Removal, 4 x 60mL, Cat. No. 900024

2100 Series Conductivity Analyzer Consumables Ordering Information:

  • 111.9mS/cm Conductivity Standard, 5 x 60mL, Cat. No. 011005
  • 12.9mS/cm Conductivity Standard, 5 x 60mL, Cat. No. 011006
  • 1413μS/cm Conductivity Standard, 5 x 60mL, Cat. No. 011007
  • 100μS/cm Conductivity Standard, 5 x 60mL, Cat. No. 011008
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text