TaqMan™ SCID/SMA Assay
TaqMan™ SCID/SMA Assay
Applied Biosystems™

TaqMan™ SCID/SMA Assay

The Applied Biosystems TaqMan SCID/SMA Assay is a multiplex real-time PCR assay that detects the SMN1 gene and TREC, asRead more
Have Questions?
Change viewbuttonViewtableView
Catalog NumberNo. of Reactions
A479274000 Reactions
A479288000 Reactions
A4792920,000 Reactions
Catalog number A47927
Price (CNY)/ 4,000 reactions
-
Request A Quote
No. of Reactions:
4000 Reactions
The Applied Biosystems TaqMan SCID/SMA Assay is a multiplex real-time PCR assay that detects the SMN1 gene and TREC, as well as the RNase P gene as an internal genomic control. For an assay that also detects KREC, please see the TaqMAN SCID/SMA Plus Assay (Cat. No. A48566).

Features of the TaqMan SCID/SMA Assay include:
• Optimized for SCID and SMA
• Direct extraction from DBS samples for reduced hands-on time and cost
• Compatible with 96- or 384-reaction protocols
• High-quality results for 96 samples within 55 min using the fast cycling protocol
• Minimal liquid-dispensing steps for easy automation

Complete solution from DBS to result
The TaqMan SCID/SMA Assay detects SMN1, TREC, as well as the RNase P gene as an internal genomic control. The assay solution contains a mixture of primers and probes for each target plus an SMN2 blocker. From DBS to result, less than 40 min of hands-on time and only four reagent-dispensing steps are required for 96-well plates. One additional pipetting transfer step from DBS lysate extraction plate to qPCR plate is needed. A real-time PCR instrument with at least five filters is required to detect the reporter dyes plus the passive reference dye.

The TaqMan SCID/SMA Assay is a multiplex real-time PCR assay that detects exon 7 of SMN1 and TREC. The assay includes the RNase P gene as an internal amplification control, verifying successful sample extraction. The assay is optimized for high specificity to SMN1, eliminating cross-detection of SMN2.

For Research Use Only. Not for use in diagnostic procedures.
Specifications
Detection MethodPrimer-probe
For Use With (Equipment)QuantStudio™ 12 k Flex, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, QuantStudio™ Dx System (in RUO Mode)
Product LineTaqMan™
Shipping ConditionDry Ice
No. of Reactions4000 Reactions
Sample TypeDNA (Genomic), cDNA
Unit Size4,000 reactions
Contents & Storage
• DNA Extract All Reagents Kit
• TaqPath ProAmp Multiplex Master Mix
• TaqMan SCID/SMA Assay