Catalog NumberDescriptionFor Use With (Application)Mass Spectrometer InterfaceMethods
WFLOW-62003Tox Explorer Collection for Quantis Plus MSAccessible quantitative performance in: Forensic toxicology, clinical research toxicology, employee drug testing, and anti-doping applicationsThermo Scientific™ TSQ Quantis™ Plus MS (Sold separately)LC-MS/MS w/RT (QQQ tubing config.)
WFLOW-62002Tox Explorer Collection for Orbitrap Exploris 120 MSHigh resolution qualitative and quantitative performance in: Forensic toxicology, clinical research toxicology, employee drug testing, and anti-doping applicationsThermo Scientific™ Orbitrap Exploris™ 120 MS (Sold separately)LC-MS/MS w/RT (HRAM tubing config.)
Catalog number WFLOW-62003
Price (CNY)/ Each
-
Request A Quote
Description:
Tox Explorer Collection for Quantis Plus MS
For Use With (Application):
Accessible quantitative performance in: Forensic toxicology, clinical research toxicology, employee drug testing, and anti-doping applications
Mass Spectrometer Interface:
Thermo Scientific™ TSQ Quantis™ Plus MS (Sold separately)
Methods:
LC-MS/MS w/RT (QQQ tubing config.)

Detect an ever-increasing number of substances at ever-decreasing concentrations. The Thermo Scientific™ Tox Explorer Collection is an all-in-one LC/MS solution that enables the world's toxicology community to solve complex analytical challenges and increase laboratory productivity.

The Tox Explorer Collection comes equipped with a standardized LC-MS/MS method, (U)HPLC column, experimentally obtained database with retention times, and LC-MS/MS instrument set-up and application training to enable smooth start-up and implementation.

  • Benefit from an all-in-one LC-MS/MS toxicology solution
  • Analyze a wide range of drug classes
  • Flexibility from a customizable single software platform
  • Choose from HRAM and QQQ MS platforms

Tox Explorer for Orbitrap Exploris 120 MS

  • Method: 15-minute LC-MS/MS with retention times (Includes HRAM tubing configuration)
  • LC: For use with Thermo Scientific™ Vanquish™ Flex Binary*
  • MS: For use with Thermo Scientific™ Orbitrap Exploris™ 120 MS*
  • HRAM Resolution: Full Scan 60K, ddMS2 15K (Orbitrap Exploris 120 maximum mass resolution is 120,000)
  • Pos/neg switching: standard
  • Column: Thermo Scientific™ Accucore™ Phenyl Hexyl 100 x 2.1 mm
  • Software: Thermo Scientific™ TraceFinder™ 5.1 software
  • CDB and Library: >1,800 compounds; experimentally obtained with true standards
  • Mass Range: m/z 40 – 3,000
  • Onsite Installation: instrument install and configuration set-up
  • Onsite Training: 2-days onsite install, support and Tox Explorer application training

Tox Explorer for TSQ Quantis Plus MS

  • Method: 15-minute LC-MS/MS with retention times (Includes QQQ tubing configuration)
  • LC: For use with Vanquish Flex Binary*
  • MS: For use with Thermo Scientific™ TSQ Quantis™ Plus MS*
  • SRM acquisition: 600 SRM/sec
  • Pos/neg switching: 5 ms
  • Column: Thermo Scientific™ Accucore™ Phenyl Hexyl 100 x 2.1 mm
  • Software: Thermo Scientific™ TraceFinder™ 5.1 software
  • CDB: >1,248 compounds; experimentally obtained with true standards
  • Mass Range: m/z 2 – 3,000
  • Onsite Installation: instrument install and configuration set-up
  • Onsite Training: 2-days onsite install, support and Tox Explorer application training

* Sold separately: Vanquish Flex Binary, Orbitrap Exploris 120 MS and TSQ Quantis Plus MS

Specifications
TypeTox Explorer Collection
Mass Spectrometer InterfaceThermo Scientific™ TSQ Quantis™ Plus MS (Sold separately)
Liquid Chromatography SystemThermo Scientific™ Vanquish™ Flex Binary (Sold separately)
MethodsLC-MS/MS w/RT (QQQ tubing config.)
SoftwareThermo Scientific™ TraceFinder™ 5.1 software
DescriptionTox Explorer Collection for Quantis Plus MS
For Use With (Application)Accessible quantitative performance in: Forensic toxicology, clinical research toxicology, employee drug testing, and anti-doping applications
IncludesStandardized LC-MS/MS method, (U)HPLC column, experimentally obtained database with retention times, and LC-MS/MS instrument set-up and Tox Explorer application training by dedicated experts
Unit SizeEach